The EC-12R/S ECG has all the characteristics of the EC-12R device but it can also be used for making stress test examinations without monitoring blood pressure. In this case BP measurement is made with a conventional BP meter and the results are manually entered into the software. Connected to the PC, the device displays sampling and ECG curves with high precision, automatically loads controls and monitors HR, ST, ABP, MET, etc. parameters. The user-friendly analyzing software offers efficient and reliable measurements.
EC-12RS 12 channel Resting and Stress test ECG System
€3,000.00 ex VAT
The EC-12R/S ECG has all the characteristics of the EC-12R device but it can also be used for making stress test examinations without monitoring blood pressure. In this case BP measurement is made with a conventional BP meter and the results are manually entered into the software.
- ECG channels: 12 simultaneous
- Sampling rate: 1000 Hz
- A/D resolution: 16 bit
- Frequency response: 0.05-150 Hz
- PC connection: Wireless Bluetooth
- Power supply: 2 X 1,2 V rechargeable batterie
- Size: 125 X 68 X 32 mm
- Weight: 140 g
- Built-in expert system to give precise diagnosis
- Small size, compact build
- Alarm to detect electrode falling off
- Treadmill, Ergometer or Master Step based diagnostic exercise
measurement system - Integrated resting and stress test ECG software with database management
Cardiospy® Rest and Stress Test Software features:
- Simple, user friendly software with multiple functions
- Precise QRS classification
- Built-in expert system
- Short and long resting ECG record
- BP measurement based on auscultation method
- Color-coded ST level, slope and ST loop graphs
- SAECG
- MET – VO2 computation
- HR, BP, load, MET graphs
- Various printable reports
- Customizable alarm and stop criteria
- Ergometer and Treadmill database
- Comparing measurements
- DICOM, GDT, MFER
- Local and network operation
- Export and import functions
Monitoring patient with continuous recording
Besides conventional or short-term resting ECG records, you can also make records lasting several hours.
Ergometer and Treadmill database
Besides 17 ergometer and 18 treadmill built-in protocols, the software also contains Master-Step and Walking Test. All protocols have been tested.
ECG Filtering to improve signal quality
Using an effective digital filtering technology, there is practically no baseline movement. The smoothing filter removes muscle and network noise components from the signals without distorting QRS complexes.
Reducing the number of faulty readings by synchronizing BP measurements
Defining blood pressure by QRS gate method effectively reduces the number of faulty measurements. Due to the integration, there is no QRS synchronic “slip”, so even in case of high heart frequency no such problem will occur.
Emergency stop when the patient feels discomfort or dizziness during continuous monitoring
In case a patient feels discomfort or dizziness during a stress test, monitoring can be extended up to 60 minutes with ST trends and blood pressure monitoring.
Picture | New Code No. | Old Code No. | System’s accessories | Quantity | Accessory name |
ACC-0SWCD-01 | 12RS-V5-02 | Yes | 1 | CD with installation software | |
ACC-CLAMP-01 | 12RS-V5-20 | No | 1 | Cable clamp | |
BAG-012RS-02 | 12RS-V5-05-B | Yes | 1 | Recorder bag (EC-12R, EC-12RS, EC-12S, wireless) | |
BAG-012RS-03 | 12RS-V5-05-C | No | 1 | Recorder bag with mechanical fastener | |
BAG-012RS-04 | 12RS-V5-17 | Yes | 1 | Patient cable bag | |
BAT-00000-02 | 12RS-V5-08 | Yes | 4 | 1.2V Rechargeable batteries (AA) | |
BEL-00000-01 | 12RS-V5-06 | Yes | 1 | Waist belt | |
500 500 | CAB-00ECG-02 | 12RS-V5-09-E | No | 1 | Glove Electrode Cable |
CAB-00L12-05 | 12RS-V5-09-C | Yes | 1 | 12 CH standard patient cable (HDMI-Snap connector) | |
CAB-00L12-06 | 12RS-V5-09-B | No | 1 | 12 CH standard patient cable (HDMI-Banana connector) | |
CAB-00QRS-01 | 12RS-V5-19 | No | 1 | TTL output cable (QRS Pulse) | |
CAB-00SUC-01 | 12RS-V5-18 | No | 1 | Interface cable for suction electrodes | |
CAB-00USB-01 | 12RS-V5-15 | Yes | 1 | Extension cable for USB-02 | |
CAB-00USB-03 | 12RS-V5-12-B | Yes | 1 | PC USB cable, 5m (USB A – USB B) | |
CAB-00USB-06 | 12RS-V5-16 | Yes | 1 | USB-SIO cable (USB A – D-SUB, for ergometer, treadmill) | |
CAS-012RS-01 | 12RS-V5-01 | Yes | 1 | Case for holding the rest and stress system | |
CHA-0004X-01 | 12RS-V5-07 | Yes | 1 | Battery charger MAXI | |
DEV-012RS-05 | 12RS-V5-04-B | Yes | 1 | EC-12R/S ECG recorder unit (BT) | |
DEV-0USBA-02 | 12RS-V5-03-A | Yes | 1 | USB-02/A Bluetooth Interface Unit (rest and stress; holter monitoring) | |
ELE-00000-01 | 12RS-V5-11 | Yes | 1 | Single-use ECG electrodes | |
ELE-CHEST-01 | 12RS-V5-10-B | No | 1 | Adult chest electrodes (1 pack / 6 pcs) | |
ELE-CLAMP-01 | 12RS-V5-10-A | No | 1 | Adult clamp electrodes (1 pack / 4 pcs) | |
PAD-00000-01 | 12RS-V5-21 | Yes | 1 | Mouse pad | |
USR-00000-01 | 12RS-V5-15-A | Yes | 1 | Installation and Update Guide | |
USR-00000-04 | 12RS-V5-15-B | Yes | 1 | User manual for rest and stress systems |
*The manufacturer maintains the right to change at any time.